Weiter Zurück Inhalt

5. Configuration for OeBB PAD Mode

5.1 Warning

In this chapter I want to show all parameters which have to be changed. But be carefully, the chapters follow the APD-2 Handbook and not the way how the configuration works really. The reason is, that if you would change the asynchronous link first, you would loose the connection to the configuration menue. Therefore you should use the automatic configuration tool I wrote, or you should read carefully what the automatic configuration program does really.

5.2 start configuration

Enter the configuration menue with typing

     1<CR>
    

You should receive the following view:

----------------------------------------------------------------------------------
      Configuration menu
     --------------------
   1) Channel
   2) Profile
   3) Link
   4) System parameters
   5) PVC
   6) Call ID
   7) NUI
   8) Alias
   9) Routing table
  10) Funnel
  11) X.32
  12) Management
  13) X.25 Multicast
  14) IP Routing
  15) ISDN configuration
  CR) Exit

    Select:                        
----------------------------------------------------------------------------------
     

In the following chapters 4.1 to 4.15 I try to describe, which settings you need for a proper OeBB X25/X.25/X.21 Connection.

5.3 Channel configuration

Press

    1<CR> 
    

to enter the channel configuration

Press

    5<CR>
    

to check channel types. You should see the following:

----------------------------------------------------------------------------------
Chan |  2  |  3  |
-----|-----|-----|
Prot |X.28 |X.28 |
----------------------------------------------------------------------------------
     

Change the channel types of link 2 and 3 if not X.28 Protocol set. Afterwards go back to configuration menue by pressing and change to menue update channel by typing

     3<CR> 
    

and enter channelnumber

     2<CR>
    

----------------------------------------------------------------------------------
      Channel   2  configuration
     -----------------------------
   1) Profile number ................. [  2  ] <===
   2) Outgoing call profile number ... [  0  ]
   3) Incoming call profile number ... [  0  ]
   4) Remote profile number .......... [  0  ]
   5) Autocall ID  ................... [  0  ]
   6) Alternate autocall ID .......... [  0  ]
   7) Autocall retries ............... [ 10  ]
   8) Autocall retry interval ........ [  5  ]
   9) Call alias ..................... [  0  ]
  10) Sub address 1 ...................[  2  ]
  11) Sub address 2 ...................[  0  ]
  12) NUI Group ID ................... [  0  ]
  13) Clear timer .................... [  0  ]
  14) Options ........................ [128  ] <===
   S) Save
  CR) Exit
----------------------------------------------------------------------------------
     

Change the parameters to the above settings.

Attention: Donīt foreget to save the changes with

     S<CR> !!!
    

After changing the parameters, duplicate line 2 to line 3 by typing

----------------------------------------------------------------------------------
        1<CR>                duplicate channel
        2<CR>                source channel
        3:3<CR>              destination channel range
----------------------------------------------------------------------------------
     

This commands duplicate channel 2 to the range of channels 3 to channel 3.

5.4 Profile configuration

Enter the profile configuration for profile 1 with typing

    2<CR> 
    

and

    3<CR> 
    

in the configuration menue. You get the following view:

----------------------------------------------------------------------------------
      Profile 1    configuration
     -----------------------------
 1) Recall char ........... [0    ]        20) Echomask ............ [0    ]
 2) Echo .................. [0    ]        21) Parity treat ........ [0    ]
 3) Data forward char ..... [0    ]        22) Page wait ........... [0    ]
 4) Idle timer............. [2    ] <===  100) Bits/char ........... [3    ]
 5) Device flow control ... [0    ] <===  101) Dv_parity ........... [0    ]
 6) Service signal ........ [0    ]       102) Stop bits ........... [0    ]
 7) Break ................. [0    ] <===  103) Special flow ........ [0    ]
 8) Discard output ........ [0    ]       104) Count fwd ........... [0    ]
 9) CR padding ............ [0    ]       105) Esc_delay ........... [0    ]
10) Line folding .......... [0    ]       106) Character break ..... [0    ]
11) Speed ................. [15   ] <===  107) Character suppress .. [0    ]
12) Pad flow control ...... [0    ] <===  108) Character substitute  [0    ]
13) Linefeed insertion .... [0    ]       109) Form feed padding ... [0    ]
14) Linefeed padding ...... [0    ]       110) Inactivity .......... [0    ]
15) Editing ............... [0    ]       111) Options ............. [0    ]
16) Character delete ...... [0    ]       112) Clr Timer ........... [0    ]
17) Line delete ........... [0    ]       113) Subaddress in CUD ... [2    ]
18) Line display .......... [0    ]       114) DNIC ................ [0    ]
19) Edit service signals .. [0    ]         C) Copy
                                            S) Save      CR) Exit             
----------------------------------------------------------------------------------
     

When you changed all parameters of profile 1, than save the profile with

     S<CR> 
    

and leave to the profile configuration menue.

5.5 Link configuration

Enter the link configuration for link 1 by activating fuction "3 Link" in the configuration menue and function "3 Update Link parameters" in the link configuration menue. You get the following view:

----------------------------------------------------------------------------------
    X.25 Link 1    configuration
   ------------------------------
 1) Address ............... [0    ]
 2) DCE (1) / DTE (0)...... [0    ]     17) LGN ...................... [0    ]
 3) Extended mode ......... [0    ]     18) Lowest LCN (LIC) ......... [3    ] <===
 4) T1 .................... [5    ]     19) Amount of Incoming LCNs .. [5    ]
 5) T3 .................... [20   ]     20) Amount of Two Way LCNs ... [5    ]
 6) N2 .................... [10   ]     21) Amount of Outgoing LCNs .. [5    ]
 7) k ..................... [7    ]     22) Internal Clock ........... [0    ]
 8) w ..................... [2    ]     23) LINE option .............. [1024 ]
 9) T10 ................... [18   ]     24) Segment Size.............. [128  ]
10) T11 ................... [20   ]     25) Xid num .................. [0    ]
11) T12 ................... [18   ]     26) NUI Group ID ............. [0    ]
12) T13 ................... [18   ]     27) Physical interface option. [0    ]
13) Packet size ........... [128  ]     28) CUG subscription ......... [5    ]
14) In call options ....... [1    ]     S) Save
15) Out call options ...... [1    ]     CR) Exit
16) Subaddress length ..... [2    ]
----------------------------------------------------------------------------------
     

When you changed all parameters of link configuration, than save the configuration with

     S<CR>
     
and leave to the link configuration menue.

5.6 Systemparameter configuration

Enter the systemparameter configuration by choosing function "4 System parameters" in the configuration menue. You get the following view:

----------------------------------------------------------------------------------
      System parameters configuration
     ---------------------------------
   1) Device ID............................. [0    ]
   2) X.28 prompt .......................... [*    ]
   3) User password ........................ [XXXXXXXXXX]
   4) Super user password .................. [XXXXXXXXXX]
   5) Herald ............................... [CHANNEL NUMBER ]
   6) Bulletin ............................. [     ]
   7) Command port sub-address ............. [0    ]
   8) Command port alternate sub-address ... [0    ]
   9) Inner communication length ........... [2    ]
  10) Xon .................................. [17   ]
  11) Xoff ................................. [19   ]
  12) Max LCN .............................. [45   ]
  13) Max AIDs per link .................... [251  ]
  14) Async Handshake Sequence ............. [;    ]
   S) Save
  CR) Exit
                 Select:                      
----------------------------------------------------------------------------------
     

Normaly there should be nothing to change. If you checked the systemparameters leave this screen and go back to the main menue.

5.7 PVC configuration

Enter the PVC configuration by choosing "5 PVC" in the configuration menue. In the first step you should check if there exists a empty pvc-configuration table. You can view the configured pvcs by choosing "4 Display PVC s" in the PVC configuration menue. You should receive the following picture:

----------------------------------------------------------------------------------
par   \   PVC     |
------------------|
Source Link       |
Source Channel/LCN|
Destination Link  |
Destination LCN   |

   Press <RETURN> to continue          
----------------------------------------------------------------------------------
     

If your PVC-configuration dosnīt look like this you should follow the reset procedure described at the end of this document and reset all parameters in the PAD and start again from the beginning with the setup procedure.

For OeBB X25 we need on the X.25 link two PVCs. In the next step we connect logicaly the two physikal links 2 and 3 to the first two PVCs on the physokal link 1, which is the X.25 connector. Links 2 and 3 are V.24/X.28 PAD Links to the OeBB X25 Applikation.

----------------------------------------------------------------------------------
1<CR>                        add PVC
1<CR>                        PVC number 1
1<CR>                        Local PVC
1<CR>2<CR>                from channel 2
2<CR>1<CR>                to channel 1
3<CR>1<CR>                PVC 1
s<CR>                        save configuration
<CR>                 leave to pvc-config-menue

1<CR>                        add PVC
2<CR>                        PVC number 2
1<CR>                        Local PVC
1<CR>3<CR>                from channel 3
2<CR>1<CR>                to channel 1
3<CR>2<CR>                PVC 2
s<CR>                        save configuration
<CR>                 leave to pvc-config-menue
----------------------------------------------------------------------------------
     

By choosing "4 Display PVC s" in the PVC configuration menue you should receive the following configuration:

----------------------------------------------------------------------------------
par   \   PVC     | 1   | 2   |
------------------|-----|-----|
Source Link       |LOCAL|LOCAL|
Source Channel/LCN| 2   | 3   |
Destination Link  | 1   | 1   |
Destination LCN   | 1   | 2   |

   Press <RETURN> to continue                  
----------------------------------------------------------------------------------
     

5.8 Call ID configuration

Normaly we donīt use Call IDs! Nothing to change here.

5.9 NUI configuration

Normaly we donīt use NUI! Nothing to change here. (NUI = Network User ID)

5.10 Alias configuration

Normaly we donīt use aliases! Nothing to change here.

5.11 Routing table configuration

Normaly we donīt use routing tables! Nothing to change here.

5.12 Funnel configuration

Normaly we donīt use the funnel facility! Nothing to change here.

5.13 X.32 support configuration

Normaly we donīt use X.32! Nothing to change here.

5.14 Management configuration

Normaly we donīt use SNMP or Event-Reporting! Nothing to change here.

5.15 X.25 Mulit Cast configuration

Normaly we donīt use X.25 Multi Cast! Nothing to change here.

5.16 IP Routing configuration

Normaly we donīt use IP addresses! Nothing to change here.

5.17 ISDN configuration

Normaly we donīt use ISDN! Nothing to change here.


Weiter Zurück Inhalt